logo commercial door repair ontario
Serving All GTA Toronto area, For any Commercial Doors, Garage Doors, Steel Doors, Aluminum Doors, Metal Doors, Wood Doors, Fire rated Doors, Glass Doors, Doors Hardware, Door Hinges, Door Closer, Exit Bar Doors, Door Locks.

COMMERCIAL DOOR REPAIR ONTARIO

Emergency Door Repair Call 24/7

Electric Strike & Mag Lock Repair in Toronto

Fob reader beeps but the door stays locked? Door will not relock after release? We repair and install electric strikes, magnetic locks and the door hardware behind your access control, for offices, clinics, condos and stores across the GTA.

✓ 24/7 emergency service✓ Licensed & insured technicians✓ Toronto & the GTA✓ Commercial doors only

When access control doors stop working

Access control is only as reliable as the door it sits on. Most of the calls we get for “the fob isn’t working” turn out to be mechanical: an electric strike that is out of line with the latch, a mag lock plate that no longer meets the magnet, or a door closer that does not pull the door shut so the lock can engage.

We focus on the door side of access control: strikes, maglocks, request-to-exit hardware, closers, hinges and frames. When the problem is in the controller or wiring panel, we tell you so and work alongside your security provider.

Electric Strike & Mag Lock Repair Toronto - Commercial Door Repair Ontario
Electric Strike & Mag Lock Repair Toronto | Call 647-931-0097

Common electric strike and mag lock problems

Strike buzzes but door will not open

The strike is releasing, but the latch is pressed hard against the keeper because the door has shifted or the closer is pulling too hard. Realigning the door and strike usually fixes it.

No click at all

No sound when the fob is used usually means power, wiring or a failed solenoid. We test the strike and replace it if it has failed.

Door will not relock

The door is not closing fully, so the latch never re-engages. Closer adjustment and hinge repair are often the fix.

Mag lock not holding

The armature plate must sit flat against the magnet. A loose plate, a bent door or dirt on the faces reduces holding force dramatically.

Door releases on its own

A worn strike, wrong fail-safe setting or a door that bounces back from the frame can leave it unsecured.

Exit button or motion sensor faults

Request-to-exit devices that fail can trap people or leave doors unlocked. We replace push buttons and check that exit hardware releases correctly.

Electric strikes vs magnetic locks

Electric strikes

An electric strike replaces the normal strike in the frame. When powered (or unpowered, depending on the setting), the keeper releases so the latch can pass. Strikes work with the existing lockset and are common on office suites, back doors and storefronts.

Fail-secure and fail-safe

A fail-secure strike stays locked if power is lost, which suits perimeter security. A fail-safe strike unlocks when power is lost. The right choice depends on the door’s role and the fire and building rules that apply to it.

Magnetic locks

A maglock is an electromagnet on the frame header with a steel plate on the door. They are simple and strong, with no moving parts, and are common on glass doors and lobbies. Maglocks release when power is cut, so they must be paired with proper request-to-exit and fire alarm release where required.

Electric strikeMagnetic lock
MountedIn the frame, behind the latchOn the header and door face
Works with existing lockYesSeparate from the lockset
Power lossFail-secure or fail-safe optionsReleases (fail-safe)
Best forOffice suites, back doors, storefrontsGlass doors, lobbies, double doors

Our access door repair process

1. Test the door mechanically first

We check that the door closes fully, the latch lines up with the strike and the maglock plate meets the magnet squarely. Many faults are fixed right here.

2. Test the locking device

We confirm voltage at the strike or maglock, check the solenoid or coil, and test release and relock.

3. Repair or replace hardware

Strikes, keepers, maglocks, armature plates, mounting brackets, door position switches and exit buttons.

4. Fix the door itself

Closers, hinges and frames are adjusted or repaired so the door reliably returns to the locked position. See door closer repair and continuous hinge and pivot repair.

5. Coordinate with your security provider

If the controller, reader or wiring needs work, we document what we found so your access control company can complete the repair quickly.

Commercial lock change and access door service in Toronto
Commercial lock change and access door service in Toronto

Fob door not opening? Call our team.

📞 647-931-0097

Doors we work on

Office suites and corporate floors

Suite entry doors with strikes and card readers, often with closers and hold-open requirements.

Condo lobbies and amenity rooms

Glass vestibule doors with maglocks, automatic operators and enterphone release. See automatic door repair.

Clinics, schools and daycares

Controlled entry with quick egress. Exit hardware and releases must work every time.

Retail back doors and warehouses

Steel rear doors with strikes, panic hardware and door contacts. See panic bar and exit device repair and steel door repair.

Safety and code considerations

Locked doors on exit routes must still allow people to leave quickly. Requirements for egress doors, hold-opens and fire alarm release come from the building and fire codes; the province publishes the Ontario Fire Code. We install hardware that supports a compliant setup and recommend confirming specific requirements with your building or fire official.

Choosing the right electric strike

Electric strikes come in many styles, and the right one depends on the door, frame and lock.

Frame type

Hollow metal frames, aluminum storefront frames and wood frames each need a strike designed for that frame, with the right body depth and faceplate.

Lock type

Cylindrical locks, mortise locks and rim exit devices each need a matching strike so the latch and deadlatch sit correctly.

Fire-rated openings

Fire doors need fire-rated strikes that keep the door latched in a fire.

Voltage and function

12 or 24 volt, AC or DC, fail-safe or fail-secure. The strike must match the access control power supply and the door’s role.

Signs your strike is the wrong type

  • The latch binds against the keeper
  • The deadlatch slips into the keeper and blocks release
  • The strike buzzes constantly or overheats
  • The door only releases if pushed or pulled first

Maglock installation tips that prevent problems

Magnetic locks are reliable when installed correctly. Most maglock complaints come from installation details:

  • The armature plate must be able to self-align to sit flat on the magnet
  • The door must close fully and squarely; closers and hinges matter
  • Mounting brackets must be solid; flexing frames reduce holding force
  • Request-to-exit devices and fire alarm release must be wired correctly
  • Glass doors need proper brackets so the magnet mounts securely

We also check that people can always exit, which is the most important part of any maglock installation.

Magnetic lock repair in Toronto
Magnetic lock repair in Toronto

Access control hardware we service

Electric strikes, magnetic locks, electrified mortise locks, electrified exit devices, request-to-exit buttons and motion sensors, door position switches, and power transfer hinges that carry wiring through the door. For the full door, see commercial lock repair and rekey and exit device repair.

Electric strike and maglock FAQ

Why does my door buzz but not open?

The strike is releasing but the latch is jammed against it, usually because the door has shifted or the closer is too strong. Realignment typically fixes it.

Can you add an electric strike to an existing door?

Yes, on most hollow metal and aluminum frames. We match the strike to your lockset and the door’s role.

Do you install card readers?

We handle the door hardware side. For readers, controllers and software we coordinate with your access control provider.

My maglock is weak. Does it need replacing?

Often the plate is loose or not sitting flat. Re-mounting and cleaning the faces restores holding force; failed coils need replacement.

Can you work after hours?

Yes. We offer 24/7 service for doors that cannot be secured. Call 647-931-0097.

Access-controlled door not opening or not locking? We can help today.

📞 Call 647-931-0097